PLUTO20CA-SR



Torque Driver

The Kolver CA Series incorporates the PLUTO (PLUs TOrque) DC-controlled electric screwdrivers design, supplied in a in-line aluminum housing with remote start for fixture mounting applications. The DC motor and solid state controls of the PLUTO are ideal for automated high volume/duty applications.

The PLUTO operates by setting a torque and RPM profile on a controller, validated back to a separate transducer or torque tester. As a result a controller is necessary for the tool to operate (purchased separately).

Unique features of this model:
  • Aluminum in-line body style
  • Remote start/stop/reverse
  • 3/8" male square drive

The torque profile includes the following parameter steps (units available for single and multi-torque applications):

  • slow start
  • adjustable speed
  • soft or hard joint option
  • high speed rundown
  • slow speed tightening to manage the moment of inertia
  • automatic reverse at cycle end
  • elapsed time auto-stop

IO included for torque reached signal and lever signal, remote start and reverse contacts

Items that ship with this unit:
  • 8 ft controller connection cable

NOTES:

  1. The heavy-duty cables and connectors, developed for robotic applications, are made of antistatic dissipative material for a safe use in ESD environment.
  2. This tool has no start/stop controls on the tool, it requires signals from the controller to operate.

Details & Specifications


Torque Range: 23.0 - 177 in-lbs
RPM Range: 210 Max Rpm
Screw Size: M5
Voltage: 40 VDC
Start Option: On driver body
Housing Option: Aluminum In-Line
RPM Control: Standard
Parameter Sets: (8) Optional